Radiator Thermostat Head

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2022-07-26 05:22

  • Browse the number:

    239

Send an inquiries

Company Profile

Taizhou UCCON HVAC Technology Co., Ltd

By certification [File Integrity]

Contact:youkong(Mr.)  

Email:

Telephone:

Phone:

Area:Beijing

Address:Beijing

Website:http://www.tzucconhvac.com/ http://youkong.sipwel.com/

Product details

Product Name

Radiator thermostat head

Model NO.

UC1002

Material

Nylon,ABS,BRASS

Color

White

Surface Finish

Polished of brass part

Size

M30*1.5

Temp.Range

0-5 set / 6-28 degree

Warranty

1 Year

MOQ

500 PCS

Packaging

Standard export packing or buyer's request


Short Description

Radiator thermostat head is which used to control the temperature stably, for example, heaters, convectors, and radiators. Our thermostatic head is available with built-in sensors or remote sensors with shut-off functions.Nylon cover with liquid heating sensor . a brass thread connector to make it stable when its working. Also with 0-5 range of the temperature from 6 degree to 28 degree. The working pressure is 10 bars to fit with most working range.


Instructions

1. Setting the temperature.

Temperature range: 6-28 °C.

Temperatures will be as follows:

For example, if you wish to set the temperature to 20 °C, choose number 3 and the thermostatic valve will close or open automatically in order to keep the temperature around 20 °C +/- 1 °C. For higher temperatures, turn to 4 or 5 and for lower ones turn to 1 or 2.

2. Use of “ * “ Mark:

When going out, you can set the valve to “ * “ and it should keep the room at a certain temperature and avoid frost (anti-freeze function).

3. Keep the shell of the thermostatic valve clean and ventilated. Do not use alcohol or bleach to clean it.


Are radiator valve heads Universal?

The radiator thermostatic valve is an automatic control valve installed on the radiator. The radiator thermostatic valve is a proportional control valve that can work without external energy. It adjusts and controls the indoor temperature by changing the flow of heating and hot water. It is an economical and energy-saving product. Its control element is a temperature bulb, which is filled with a temperature-sensing substance. When the room temperature rises, the temperature bulb expands to close the valve, reducing the supply of hot water to the radiator. When the room temperature drops, the process is reversed, so that the temperature control can be achieved. Purpose. The radiator temperature control valve can also adjust the set temperature, and can automatically control and adjust the hot water supply of the radiator according to the set requirements.

The connection between your valve and the radiator is standard across all moderns radiators and valves. Most of the time it's 15mm, but measuring your pipes will confirm.


How to install the radiator thermostat head?

Devices like thermostatic radiator heads are designed to regulate heating temperatures. It can make more reasonable utilization of heating medium and save money. The correct choice is the guarantee of the use effect. When installing the thermostatic head on the radiator, its connection position does not depend on the type of radiator. In any case, it is the pipe that directly supplies the radiator. For a device to work properly, air must circulate around it uninterruptedly.


Wiring suggestion: We give the connection suggestion for the thermostatic head. But there are also general installation conditions:

1. The enclosure must be protected from direct ultraviolet radiation. Otherwise the instrument will not work accurately.

2. The thermal head must be exposed. It cannot be hidden by any protective piping or furniture.

3. The equipment cannot be placed above the heating tube. In this case, there will be differences in room temperature and the area around the handpiece.

4. If the equipment is actually insulated, a bypass pipe must be arranged, or a bypass valve should be placed in the area of the supply and return pipes.

5. The piping to be connected cannot put pressure on the valve body.

When installed, the thermostatic head regulator must be set to maximum. This will ensure the normal operation of the device. Before installation, the water or other heating medium in the circuit must be turned off and then drained. Its position must be parallel to the ground. This location is guaranteed not to be affected by heating.


Assembly sequence of the device

When installing, the pipe should be cut first, and it should be carried out at a certain distance from the radiator. The next step is to remove the existing shut-off valve. Next, separate the stem from the valve and screw it into the radiator plug. Install the pipes by pre-assembly, and connect the pipes. All that's left is to adjust the temperature by turning the thermostat knob until the grooves in the case correspond with the markings for the set temperature.

Avoid over-tightening the thermostat's nuts as their material is quite soft. It is best to use a torque wrench.

It is important that the arrows on the body point in the direction of hot water flow in the system. Otherwise, the work will be wasted and nothing will succeed. The thermostatic head can be installed on both sides of the water inlet and outlet.

Don't disregard the manufacturer's recommendation for the height at which the device is mounted, as it is calibrated to the temperature at that height. Generally speaking, it is 0.4-0.6 meters from the ground.

But not all batteries get water from the top, they also come from the bottom. If there is no suitable sample at altitude, the solution is to set the thermostat to a lower temperature.

Since it's cooler on the floor and the device is set to the temperature it should be on top of the battery, the room will be hot. To avoid this, a thermostatic head with a remote sensor can be installed. You can also choose to set the regulator yourself.


In order for the device to work properly, a preset is required. Set the thermometer at a certain point, then adjust:

Turn the thermostat head to the left until it stops so that the flow of heating medium is fully open.

Wait for the temperature to rise 5-6° from the initial value.

Rotate the handpiece fully to the right.

When the temperature drops to the desired value, gradually unscrew the valve. If the heatsink is noisy and the case gets hot, stop.

The last position of the thermostat head corresponds to the comfort temperature. This is the temperature that will be maintained.


Notes on Installation

The valve should be placed at the entrance of water into the radiator. In order for the thermostatic valve to function properly, please make sure it is not covered or blocked by curtains or furniture.


Application


Certificates


UCCON Company profile

UCCON is a professional TRV manufacturer and Manifolds and accessory , Radiator valve, Safety unit,Electric thermal actuator fittings .As the professional fluid solution provider, with over 5 years of industry experiences.

1.Monthly production capacity of 1 million sets, enables quick delivery with lower costs.

2.Quality-oriented production process, test each valve during production

3.Intensive QC and on-time delivery, to make quality reliable and stable

4.Offer professional, comprehensive and cost-effective solutions

5.Timely and varied advisory services

6.Reliable and continuous after-sales service


FAQ

Q: Are you trading company or manufacturer?

A: We are professional manufacturer specialized in orthopedic and sport products. And we trade our products with our clients directly.

Q: Can you do OEM and ODM?

A: Yes, OEM and ODM are both acceptable. The material, color, style can customize, the basic quantity we will advise after we discuss.

Q: Can we use our own logo?

A: Yes, we can print your private logo according to your request.

Q: How many packaging do you have?

A: We have five packages including PE bag, hand bag, zip lock bag, colorful box and white box currently.


If you are looking for Radiator thermostat head suppliers,please feel free to contact us for the best price.We will provide the most professional technology and high-quality service, and look forward to our first pleasant cooperation.

http://www.tzucconhvac.com/