Extraction Condensing Steam Turbine

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Sichuan

  • Validity to:

    Long-term effective

  • Last update:

    2021-11-24 23:11

  • Browse the number:

    429

Send an inquiries

Company Profile

Dongturbo Electric Company Ltd

By certification [File Integrity]

Contact:scdtdq(Mr.)  

Email:

Telephone:

Phone:

Area:Sichuan

Address:Sichuan

Website:http://www.steamturbo.net/ http://scdtdq.sipwel.com/

Product details

Products Brief Introduction:

1. Extraction Condensing, one of the most versatile setups in terms of operation and intricate in terms of design. It provides a constant pressure steam through a controlled extraction at various loading conditions of the turbine-based on seasonal variations.

2. A control valve integrated with the steam path is provided at a predetermined stage. A partial steam flow is drawn out of the turbine at a constant pressure as per the process requirement. There are basically two types control valves a) Diaphragm, b) Passing/Throttle Valve that controls the flow of steam at a preset pressure accommodating the seasonal variation of turbine load.

3. The control system works on a closed loop feedback mechanism. The pressure at the user end is measured and a feedback is provided to the control system. Based on this error signal the feedback control system actuates a control valve designed to vary the area of the valve aperture and thereby regulate the pressure. This setup is applied for processes where the steam pressure is a critical parameter.

4. In some cases a nozzle/port is provided at a predetermined stage and an un-controlled high-pressure steam flow/bleed is drawn out of the turbine. This tap is provided before the controlled extraction in the steam path of turbine. Its utility is found mainly in LP heating requirements like de-aerator and processes.

5. Controlled/ Un-controlled condensing type turbines are used in Co-generation application and offer maximum cycle efficiency to the user.


Main Specifications

Model

Power

(KW)

Inlet

Extraction

exh pressue

(MPa)

Steam consum-ption

(kg/kw.h)

Rated Speed

(rpm)

Overall Dimensions L×M×H

(mm)

Pressure

(MPa)

temp

(℃)

Flow

(T/h)

Pressure

(MPa)

Temp

(℃)

Flow

(T/h)


Extraction type

*C1.5-2.35/0.49

1500

2.35

390

17

0.49

240

10

0.0078

11.3

5600

4136×1920×1860

*C1.5-23.5/0.98

1500

2.35

390

18.9

0.98

300

12

0.0078

12.6

5600

4136×1920×1860

*C1.5-23.5/0.49

1500

3.43

435

16.2

0.49

240

10

0.0078

10.8

5600

4136×1920×1860

*C1.5-3.43/0.98

1500

3.43

435

18.5

0.98

300

12

0.0078

12.3

5600

4136×1920×1860

*C1.5-3.43/1.37

1500

3.43

435

19

1.37

346

12

0.0078

12.7

5600

4136×1920×1860

C3-2.35/0.49

3000

2.35

390

24

0.49

257

12

0.0072

8.0

3000

4266×2555×2350

C3-2.35/0.588

3000

2.35

390

32.5

0.588

266

20

0.0072

10.83

3000

4266×2555×2820

C3-2.35/0.98

3000

2.35

390

34.4

0.98

310

20

0.0072

11.5

3000

4319×2555×2350

C3-3.43/0.49

3000

3.43

435

28

0.49

258

20

0.0072

9.33

3000

4266×2555×2820

C3-3.43/0.98

3000

3.43

435

27.4

0.98

320

15

0.0072

9.13

3000

4319×2555×2820

C6-3.43/0.49

6000

3.43

435

57.5

0.49

248

45

0.0072

9.58

3000

4266×2555×2820

C6-3.43/0.98

6000

3.43

435

66.4

0.98

311

45

0.0072

11.07

3000

4266×2555×2820

C6-3.43/1.27

6000

3.43

435

69.1

1.27

321

45

0.0072

10.48

3000

4295×2555×2450

C6-4.9/0.49

6000

4.9

435

44

0.49

218

25

0.0059

6.93

3000

4798×2705×2460

C6-4.9/0.98

6000

4.9

435

53.7

0.98

276

35

0.0055

9.0

3000

4810×2705×2460

C12-3.43/0.49

12000

3.43

435

88

0.49

257

50

0.0049

7.04

3000

6225×3650×3650

C12-3.43/0.98

12000

3.43

435

102.1

0.98

305

60

0.0049

8.25

3000

6225×3650×3650

C12-4.9/0.49

12000

4.9

435

81.4

0.49

202

45

0.0049

6.39

3000

6225×3650×3650

C12-4.9/0.98

12000

4.9

435

93

0.98

270

50

0.0049

7.42

3000

6126×3650×3650


http://www.steamturbo.net/